ODF E Type Unit is superior to congeneric products on the market. It is designed for the fiber optic communication equipment room. There is a chain which connects the door to the cabinet, making the door in the horizontal state during operation. The chain is made of aluminum alloy, looking attractive and durable. It has the function of cable fixation and protection, cable terminating, wiring, distribution and protection of fiber cores and pigtails. It can be assembled as an optical distribution frame, or in multiplex distribution frame together with digital distribution unit and audio distribution unit. Its flexible configuration, simple installation and easy operation make it become one of the indispensable equipment in optical cable network.
BESTSELLERS
PRODUCT SPECIFICATIONS
Optical Distribution Frame Unit
Item No. Net size Capacity (double capacity for LC adapter) Single weight(kg) Outer packing quantity(pcs)
SS-E-12 482*260*1U 12F 3.5 6
SS-E-24 482*260*2U 24F 4.6 4
SS-E-48 482*260*3U 48F 6.3 4
SS-E-72 482*260*4U 72F 8 2
SS-E-96 482*260*6U 96F 12.6 2
SS-E-144 482*260*8U 144F 15.4 1



Features

  • All the performance indexes meet the requirements of national YD / T778-2011 standard.
  • Metal plate unit box structure, 19'' standard installation with good universality.
  • The component for opening the door adopting snap, has compact structure and beautiful appearance.
  • It integrates fiber splicing, storage and wiring. Each splicing module can be extracted separately satisfying the operation in or out of the box.
  • Support the multiple adapters: SC, FC, ST, LC, etc.

Main Technical Index

  • Environmental requirements:
  • Working temperature: -5℃~+40℃
  • Relative temperature: ≤85%(+30℃)
  • Atmospheric pressure: 70kpa~106kpa
  • Storage temperature: -25℃~+55℃ 3.2

Technical Index

  • Working wavelength: 850nm 1310nm 1550nm
  • Connector loss (Including interchangeability and repetition): ≤0.5dB
  • Return loss: APC movable connector≥60dB, UPC movable connector≥50dB, PC movable connector≥45dB.
  • Pull and insertion service life: no mechanical damage after 500 times of pulling and inserting repeatedly. Additional loss of insertion ≤0.2dB, return loss≤5dB
  • Withstand voltage between high voltage protective grounding device and frame≥3000V(D.C)/1min, No breakdown, No flash-over.
  • Insulation resistance between high voltage protective grounding device and frame≥1000MΩ/500V(D.C)
SCOPE OF APPLICATION
  • Data Center

  • FTTX Solutions

  • Broadband Distribution System

PRODUCT PACKAGING
  • Specific labels as request

  • 1pc each package

  • 1pc/2pcs/3pcs/5pcs with carton box 

TECHNICAL DOCUMENT
COMPATIBLE
OEM&ODM SUPPORTED
  • OEM Manufacturer
    SEESUO provides tailored OEM productsbased on clients' designs and specs
  • ODM Manufacturer
    SEESUO boasts rich R&D experienceand top-notch production management
  • Customized production
    SEESUO provides tailored product design,development, and flexible manufacturing.
  • R&D cooperation
    SEESUO adapts swiftly to market changescollaborating with customers in R&D
PRODUCT PROBLEM
  • Are ODF Units adaptable to different network sizes or connection volumes?
    Yes, ODF Units come in a variety of sizes and configurations to fit both small and large network requirements. For high-density installations, ODFs are available with options for large-scale fiber connections, while smaller units are ideal for limited setups. This adaptability makes ODF Units suitable for both growing and established networks.
  • How can an ODF Unit improve network safety in a data center?
    An ODF Unit keeps fiber cables securely organized, preventing accidental disconnections and minimizing trip hazards. By routing cables through designated paths, it also reduces the likelihood of fiber damage, protecting network stability. This setup contributes to a safer work environment in data centers where cable management is essential for safety.
  • What maintenance practices should be followed to ensure an ODF Unit operates effectively?
    Regular maintenance of an ODF Unit involves cleaning connector ports to avoid signal interference from dust, checking for loose connections, and ensuring cables aren’t bent or stressed. By performing periodic inspections and organizing fibers properly, you’ll enhance network reliability and minimize potential connectivity issues, ensuring consistent performance.
PRODUCT TESTING
  • Conductivity Testing
  • Protection Testing
  • Flexibility Testing
  • Resistance Testing
  • Tensile Testing
  • Attenuation Testing
  • Security Testing
  • Expansion Testing
  • Thermal Testing
  • Resistance Testing
OUR FACTORY
Our certificate
FEATURED REVIEWS
  • Alejandra Muñoz
    Mexico
    5.0
    I upgraded my network with the E Type optic distribution frame alongside a Huawei MA5800. The design maximizes space for my fibers, and access to connections has never been easier—definitely worth it!
  • Kehinde Adesina
    Nigeria
    5.0
    This E Type frame is just what I needed for my high-density deployment with a Juniper QFX switch. It keeps everything tidy and organized, making my setup look professional and efficient!