OEM
OEM
Provide custom product specifica-tions, icons, logo, packaging.
ODF B Type Unit is designed with door for the fiber optic communication equipment room. It has the function of cable fixation and protection, cable terminating, wiring, distribution and protection of fiber cores and pigtails. It can be assembled as an optical distribution frame, or in multiplex distribution frame together with digital distribution unit and audio distribution unit. Its flexible configuration, simple installation and easy operation make it become one of the indispensable equipment in optical cable network.
BESTSELLERS
PRODUCT SPECIFICATIONS
Optical Distribution Frame Unit
Model Net size (mm)
 
Inner carton dimension(mm)
 
Inner carton weight(kg)
 
Outer carton dimension(mm)
 
 
Outer carton weight(kg)
 
Units /carton(pcs)
 
SS-B-24 480*300*2U 450*320*110 5.7 475*340*480 24   4
SS-B-48 480*300*3U 475*335*170 7.7 500*350*540 24   3
SS-B-72 480*300*4U 470*335*220 9.8 500*350*460 21.1 2
SS-B-96 480*300*6U 470*335*290 13.7 500*350*460 28.9 2
SS-B-96 480*300*8U 470*335*380 16.5 470*335*380 18 1



Features

  • All the performance indexes meet the requirements of national YD / T778-2011 standard.
  • Metal plate unit box structure, 19'' standard installation with good universality.
  • Full modular design and frontal operation.
  • It integrates fiber splicing, storage and wiring. Each splicing module can be extracted separately satisfying the operation in or out of the box.
  • Support the multiple adapters: SC, FC, ST, LC, etc.

Main Technical Index

  • Environmental requirements:
  • Working temperature: -5℃~+40℃
  • Relative temperature: ≤85%(+30℃)
  • Atmospheric pressure: 70kpa~106kpa
  • Storage temperature: -25℃~+55℃ 3.2

Technical Index

  • Working wavelength: 850nm 1310nm 1550nm
  • Connector loss (Including interchangeability and repetition): ≤0.5dB
  • Return loss: APC movable connector≥60dB, UPC movable connector≥50dB, PC movable connector≥45dB.
  • Pull and insertion service life: no mechanical damage after 500 times of pulling and inserting repeatedly. Additional loss of insertion ≤0.2dB, return loss≤5dB
  • Withstand voltage between high voltage protective grounding device and frame≥3000V(D.C)/1min, No breakdown, No flash-over.
  • Insulation resistance between high voltage protective grounding device and frame≥1000MΩ/500V(D.C)
SCOPE OF APPLICATION
  • Data Center

  • FTTX Solutions

  • Broadband Distribution System

PRODUCT PACKAGING
  • Specific labels as request

  • 1pc each package

  • 1pc/2pcs/3pcs/4pcs with carton box 

TECHNICAL DOCUMENT
COMPATIBLE
OEM&ODM SUPPORTED
  • OEM Manufacturer
    SEESUO provides tailored OEM productsbased on clients' designs and specs
  • ODM Manufacturer
    SEESUO boasts rich R&D experienceand top-notch production management
  • Customized production
    SEESUO provides tailored product design,development, and flexible manufacturing.
  • R&D cooperation
    SEESUO adapts swiftly to market changescollaborating with customers in R&D
PRODUCT PROBLEM
  • What are the key differences between the ODF Unit - BType and other models in the market?
    The ODF Unit - BType stands out with its enhanced density and scalability. It offers more fiber ports per unit, allowing for more efficient use of space. Additionally, its advanced cable management system ensures cleaner, neater installations compared to traditional models, reducing the risk of cable tangling and damage.
  • How does the ODF Unit - BType support high-density fiber optic deployments?
    The ODF Unit - BType is specifically engineered for high-density fiber deployments. It features a compact, yet modular design that maximizes port density while maintaining ease of access. This allows for the seamless integration of large numbers of fibers, making it ideal for data centers and other high-capacity networking environments.
  • Is the ODF Unit - BType suitable for both indoor and outdoor applications?
    Yes, the ODF Unit - BType is versatile enough for both indoor and outdoor use. Its rugged construction and weather-resistant materials ensure it can withstand a range of environmental conditions. Whether you're deploying it in a data center or an outdoor cabinet, the ODF Unit - BType provides reliable performance and long-lasting durability.
PRODUCT TESTING
  • Conductivity Testing
  • Protection Testing
  • Flexibility Testing
  • Resistance Testing
  • Tensile Testing
  • Attenuation Testing
  • Security Testing
  • Expansion Testing
  • Thermal Testing
  • Resistance Testing
OUR FACTORY
Our certificate
FEATURED REVIEWS
  • Priscila Alves
    Brazil
    5.0
    This B Type optic distribution frame has streamlined my large deployment with a Cisco ASR 9000. The spacious design is great for high-density connections, and it makes troubleshooting so much easier!
  • Bongani Sithole
    South Africa
    5.0
    I recently installed the B Type frame for my home lab with a Juniper EX switch. It provides ample room for all my fibers and looks professional—definitely enhances my setup!